HT-CC20ABP Battery Charge/Discharge Test Machine
HT-CC40ABP Battery Charge/Discharge Test Machine
(For more specifications, please contact us. )
Brand Name: | Heltec Energy |
Origin: | Mainland China |
Warranty: | One year |
MOQ: | 1 pc |
Battery Type: | Lead-acid battery, lithium-ion battery, other battery |
Channels: | Single group (for Battery Pack) |
Measuring Voltage Range: | 9-99V |
Single package size: | 60X57X27 cm |
Single gross weight: | 15.000 kg |
Application: | Used for battery capacity (charge & discharge) test./Battery capacity Tester |
The Battery Charge Discharge Test Machine Comparison
Product Model | HT-CC20ABP | HT-CCC40ABP |
Discharge cut-off voltage | 9~99V adjustable,adjustable range 0.1V | |
Charging voltage range | 9~99V adjustable,adjustable range 0.1V | |
Discharge current | 9V-21V:0.5-10Aadjustable21V-99V:0.5-20Aadjustable | 0.5 to 40A constant current, adjustable current 0.1A |
Charging current | 0.5-10A adjustable | Adjustable from 0.5 to 20A,current adjustable from 0.1A |
Charge cut-off current | 0.1-5A 0.1A is adjustable | |
Maximum number of cycles | 99 times | 16 times |
Cycle last charge capacity preset | 0-99AH(0 indicates no preset) | |
Cyclic shelving time | 0-20 minutes adjustable | |
Charge/Discharge voltage accuracy | ±0.03V | |
Charge/Discharge current accuracy | ±0.03A |
1. Lithium Battery Charge/Discharge & Equalization Repair Instrument *1set
2. Anti-static sponge, carton and wooden box.
※ The battery capacity tester with protection function of positive and negative polarity reverse connection
※ Our battery capacity tester has Intelligent cooling fan
※ The battery capacity tester with special LCD screen, all data at a glance
※ The battery capacity tester with high precision, flexible setting, to meet different charging and discharging requirements
HT-CC20ABP Battery Charge Discharge Test Machine Videos
HT-CC40ABP Battery Charge Discharge Test Machine Videos
Heltec Battery Capacity Tester's working modes:
Power socket
|
Mode description
|
00
|
Historical cyclic data query mode
|
01
|
Capacity test
|
02
|
Standard charge
|
03
|
Start with discharge and end with charge, cycle number 1-16 times
|
04
|
Start with charge and end with charge, cycle number 1-16 times
|
05
|
Start with discharge and end with discharge, cycle number 1-16
times |
06
|
Start with charge and end with discharge, cycle number 1-16 times
|
07
|
Networking mode (automatically changed to this mode
when the computer starts the device) |
Jacqueline: jacqueline@heltec-bms.com / +86 185 8375 6538
Sucre: sucre@heltec-bms.com / +86 136 8844 2313
Nancy: nancy@heltec-bms.com / +86 184 8223 7713